When you evaluate faceting rough, you decide where the finished gemstone will sit inside it. Preforming and dopping turn that decision into a physical setup. The most important reference during this stage is the centre and axis chosen for the finished stone. On irregular rough, that axis can sit visibly off-centre relative to the outer silhouette.
In this chapter, we will focus on how to preform and dop a gemstone, ensuring you have a clear understanding of the essential steps involved.
In Chapter 1, you learned how to evaluate faceting rough and choose an orientation. In Chapter 2, you learned to read a faceting diagram and check the machine. This chapter brings those steps together using the same amethyst. We will prepare it for a pavilion-first workflow, with a 7.50 mm round brilliant shifted toward the clean side of the rough to clear a mapped fracture.
Table of Contents
1. Transfer the cutting plan to the rough
Before grinding, find the features that let you orient the rough the same way each time you pick it up. Use your original photographs or sketch to identify the fracture side, the intended table side and a recognisable edge. Mark a reference on sound material that will survive the next preparation step. On a lightly frosted stone, a small mark can disappear as soon as the surface is ground. Keep a second reference on an adjacent face or in a close-up photograph.
Transfer three parts of the plan:
- The future table direction. View the rough along the intended face-up direction. This direction will become the dop axis in the initial pavilion-first setup.
- The design centre. Locate the point where that axis intersects the planned bonding face. For the amethyst, this point is shifted away from the fracture. Locate it from the mapped design envelope and your reference edges.
- The girdle position. Mark its approximate level on two sides. This makes it easier to tell whether a chip or hollow affects the crown, the girdle or the pavilion.
On an oval, rectangle or deliberately oriented bicolour design, add a mark for the intended long axis or the chosen direction of the colour boundary. Record its relationship to a known index position when mounting the dop. A round brilliant gives you more freedom to rotate the facet pattern, but rotation can still matter if you are deliberately placing an inclusion or colour boundary relative to a facet.
2. Preform in small steps and preserve the useful volume
A preform is the rough after preliminary shaping. Its purpose is to remove obvious waste, expose critical features and leave a blank that can be mounted and cut predictably. The amount of shaping depends on the piece. A compact piece may need only a bonding flat and selective trimming. A lopsided piece or one with heavy matrix may need more preparation before the design can be positioned accurately.
Start by identifying the waste that you can remove with the greatest confidence. Work from outside the design toward the marked outline, inspecting again as each important area becomes visible.
- Remove obvious excess first. Take off projecting material or matrix well outside the planned crown, girdle and pavilion. Keep a recognisable reference edge until the planned axis is transferred.
- Expose the limiting area gradually. Near a fracture, make progress in small increments and inspect under reflected and transmitted light. Follow its visible trace from two directions. A new ground surface may reveal that the fracture extends farther than it first appeared.
- Leave stock around the intended outline. Preserve material beyond the finished girdle faces for final sizing, cleanup and any small centring correction. Check the sides individually. One narrow sector can set the maximum size for the whole round.
- Keep the pavilion end blunt. Leave sufficient stock for the pavilion breaks and their temporary centre point. The final culet will be established later through the indexed cutting sequence.
- Recheck the profile. View the preform from two perpendicular sides. Check the crown envelope, pavilion envelope and bevelled or chipped areas separately. A large total thickness is useful only where the design fits within it.
Use wet equipment intended for lapidary grinding and follow the machine and abrasive manufacturers’ instructions. Quartz can generate respirable crystalline silica during grinding. Use appropriate exposure controls, wear eye protection, and remove slurry while it is wet so it does not become a source of airborne dust. Keep hands clear of moving parts and use a suitable holder or fixture when the piece is too small to control securely.

Set the allowance from the stone in front of you
Leave more stock where the rough is irregular, the fracture position is uncertain or the preforming abrasive has left marks that need to be removed. Work closer to size only after you can read the boundary clearly. A fixed allowance applied all the way around can conceal the one place where the design has already run out of material.
On the amethyst, the fracture-side shoulder is more important than the largest width you can read with callipers. If the clear portion falls inside the planned girdle line, update the plan. Compare a further shift in the centre with a smaller diameter, then check both side views again.
3. Prepare the bonding flat and choose the first dop
In a pavilion-first cut, the first dop is normally attached on the future crown side. Prepare a bonding flat large enough to support the dop face and orient it approximately parallel to the planned table. Place this preliminary surface at or above the position planned for the finished table, allowing for surface cleanup during crown cutting. An overground bonding flat can consume crown height before the pavilion has been started.
Prepare the flat in short passes. Check from two perpendicular side views that its inclination still matches the intended table plane. Dry-fit the dop onto it. The face should sit without rocking, with useful contact reaching around the dop face. If the dop bridges an irregular patch or tips when lightly seated, improve the flat or select a more suitable dop. A thick wedge of adhesive makes the final alignment harder to judge.
For a round pavilion-first project, a flat-faced dop is a practical starting choice. The ULTRA TEC V5 manual suggests a flat dop between approximately one-half and three-quarters of the projected finished diameter. At 7.50 mm, that range is 3.75–5.63 mm. A 4–5 mm flat dop is a reasonable candidate for the amethyst, provided it seats on sound material and clears the quill, lap and intended cutting path. Check the actual faces and mounting geometry of the dops you own.
A larger dop can offer more bonding area if it fits entirely on the flat. A smaller one may give better clearance where the stone narrows or where a broad dop would overlap a fracture or chip. Avoid sizing the dop from the rough’s maximum width. Base the choice on the usable flat, the finished geometry and the access you need on the machine.

4. Choose the adhesive as part of the cutting plan
Choose a bonding method that suits the stone, the dop, the coolant and the later transfer. Decide how the first bond will be released before applying it. When you transfer the gemstone to expose the crown, the release method has to be compatible with the stone and the second bond.
| Bonding method | Why a cutter might choose it | What to check |
|---|---|---|
| Faceting dop wax | The wax allows centring adjustments while it is workable. | Check the material’s tolerance of heat and rapid temperature change. Follow the wax system’s instructions for application and release. |
| Two-part epoxy suitable for the application | A room-temperature system can give time to align the stone in a fixture. | Check the mixing ratio, working time, cure schedule, coolant compatibility and release method for that product. Prevent movement during cure. |
| Cyanoacrylate suitable for the application | A rapid bond can be useful when the flat fits the dop closely and the alignment can be set promptly. | Check the product’s working time and handling precautions. Rehearse centring before the adhesive touches the stone and allow the bond to reach the specified stage for use. |
GIA notes that abrupt temperature changes can fracture amethyst. For this example, use a suitable room-temperature epoxy on the sound portion of the bonding flat and choose a release procedure compatible with the specimen. Keep uncured adhesive off your skin, ventilate the work area, and follow the product’s technical and safety data. A bond that feels firm enough to handle can still be short of its specified cure.
5. Centre the dop, control tilt and preserve rotation
A mount can be centred from above and still be tilted in profile. Check these three aspects separately:
| Check | What it controls | How to inspect it |
|---|---|---|
| Centring | Where the dop axis passes through the rough. | Sight along the dop axis and compare it with the planned centre using the marked references or a centring fixture. |
| Tilt | Whether the dop axis is perpendicular to the intended table plane. | Inspect two perpendicular side views and verify that the dop face seats evenly against the bonding flat. |
| Rotation | Which direction around the stone corresponds to the index reference. | Compare a marked edge, long axis or colour boundary with the dop’s keyed orientation or a recorded index position. |
Clean and dry both bonding surfaces according to the adhesive instructions. Keep the dop shaft clean where it seats in the quill. Place a scratch mark or ink reference outside the bonding area if a mark is needed there. Dry-fit the rough and rehearse the placement before mixing or opening the adhesive.
Apply enough adhesive to wet the intended contact area. Bring the flat and dop together without forcing the joint dry, align the marked centre, and hold the assembly in a stable position for the prescribed cure. Use only light restraint to hold the position. Heavy clamping can shift the rough or squeeze adhesive unevenly from the joint. Check the centre and tilt once more while the adhesive is still workable, then leave the assembly undisturbed.
Bench geometry · Why a slight tilt matters
Across a planned diameter of 7.50 mm, a 1° tilt between two reference planes corresponds to a height difference of about 0.13 mm from one side to the other. The estimate is 7.50 × tan(1°). In the Classic round brilliant from Chapter 2, the nominal girdle thickness at this diameter is 0.15 mm.
That comparison gives you the scale of the error. It does not predict the finished girdle thickness directly. A cutter can sometimes recover by changing where the design sits, provided there is enough stock and the intended orientation can still be achieved. Correcting the mount before cutting preserves more options.
6. Worked example · How much stock does a centring error consume?
Return to the 8.00 ct amethyst rough from Chapter 1. The intended stone is a 7.50 mm round, shifted away from the mapped fracture. For the Classic design, the finished profile requires approximately 1.64 mm of crown height, 0.15 mm of girdle thickness and 3.50 mm of pavilion depth. The total is 5.28 mm, calculated before rounding the individual dimensions. The preform must also leave appropriate stock for cleanup.
For this exercise, treat the proposed girdle as a circular envelope when checking the rough. The target envelope has a 3.75 mm radius. Suppose inspection shows that the nearest usable edge in the girdle plane is 3.95 mm from the intended axis, toward the fracture. That gives you 0.20 mm of radial stock on the limiting side.
| Position of the mounted axis | Usable radius toward the limiting edge | Stock outside the 7.50 mm envelope |
|---|---|---|
| On the planned centre | 3.95 mm | 0.20 mm |
| Shifted 0.10 mm toward the fracture | 3.85 mm | 0.10 mm |
| Shifted 0.20 mm toward the fracture | 3.75 mm | 0.00 mm |
In this example, the first tenth of a millimetre consumes half the stock on the limiting side. The other side may still look generous, and the total width across the blank can stay the same. That is why measuring only the blank’s width can miss a mounting error.
On an irregular preform, check more than two directions. Compare the rough with the intended envelope at the girdle, then check the crown and pavilion in profile. If the usable margin depends on a fracture boundary you cannot locate confidently, repeat the inspection before choosing whether to redop or revise the finished size.
7. Inspect the mounted preform before starting the lap
After cure, check the joint under magnification. Look for visible lifting, a large void near the edge, contamination, or any sign that the stone moved while curing. Seat the dop in the quill using the machine’s registration system and tighten it as specified. Keep the motor off for the following checks.
- Sight along the dop axis. Identify the planned centre and compare the surrounding stock with your notes. Index the stone through opposite positions to bring the limiting edges into view.
- Check both profiles. Confirm that the bonding flat and planned girdle reference have the intended relationship. Inspect the fracture side and verify that the pavilion end still offers adequate depth.
- Rehearse the first cutting position. Set the angle and first index from your diagram. Lower the assembly only far enough to judge clearance. Verify that the stone can reach the working area without the dop, quill or any fixture contacting the lap, lap nut or splash pan.
- Record the setup. Note the dop diameter, adhesive, cure conditions, registration mark, target diameter and any revised fracture clearance. Keep the first tier and the fallback diameter beside the machine.
A small wobble in the outline can come from the irregular preform. Compare the movement of the planned reference marks or a known straight dop before diagnosing machine runout. If the mounting error would put the fracture inside the design or take away the stock needed to clean the girdle, redop or revise the plan before making a powered cut.
Practice exercise · Mount a blank to a marked centre
Use a sound practice blank with a prepared flat. Mark an intended centre that is slightly offset from the blank’s visual centre. Make a second mark on an adjacent face so you can recover the position once the dop covers the flat. Dry-fit the dop and check it end-on and from two sides. Bond the blank, allow the adhesive to cure, and repeat the same checks in the quill.
Write down which reference was easiest to reproduce and how much radial stock remains on the narrowest side. Repeat the exercise on practice material until you can mount to the planned centre consistently. That is the skill you will use when the next piece has an expensive colour zone to preserve or a fracture close to the intended girdle.
References & Further Reading
- United States Faceters Guild — The Standard Round Brilliant and Some Common Variations — the Classic design and proportions used for the 7.50 mm amethyst example.
- ULTRA TEC — V5 Operator’s Manual — see sections 4.1 and 6.2.2–6.2.3 for dop registration, the preliminary flat and flat-dop sizing.
- Facetron Operator’s Manual, hosted by the United States Faceters Guild — an alternative machine-specific approach to the initial flat dop and wax mounting.
- United States Faceters Guild — Faceting Machine Alignment — how to assess lap, platen and mast alignment when a problem persists across mounts.
- GIA — Amethyst Care and Cleaning Guide — amethyst’s stability and sensitivity to abrupt temperature changes.
- CDC/NIOSH — Safe Work Practices for Crystalline Silica — exposure controls for dust generated by work on silica-bearing materials.
- WEST SYSTEM — Preventing Overexposure to Epoxy — general precautions for handling uncured epoxy. Use the technical and safety data for the adhesive selected for your own setup.




